Seeing a pulse supply rated for very high peak power, the first reaction is often "that machine must run hot". In reality, thermal behaviour under pulse duty differs completely from continuous duty: what sets temperature rise is average loss, not peak power. Understanding that is the key to designing cooling properly and to reading power ratings on a datasheet.
| Duty | Thermal behaviour |
|---|---|
| Continuous high current | Loss is continuous; temperature rise depends on cooling capacity |
| Low duty pulse | Peak loss is large but brief; average may stay modest |
| High repetition rate | Switching loss accumulates and can dominate |
| Short overload | Depends on thermal time constant; short pulses are absorbed by thermal mass |
Even the best thermal design depends on the installation: keep air inlets unobstructed, clean filters and ducts regularly, leave spacing in multi-unit cabinets and keep ambient temperature within limits. These daily matters often determine real service life more than the cooling scheme itself. See pulse power supplies and high-frequency pulse supplies; more solutions are in the pulse power category.