How to Size a Pulse Power Supply: Peak Current, Average Current and Duty Cycle

2026-10-28
How to Size a Pulse Power Supply: Peak Current, Average Current and Duty Cycle - Nenghua Power
Photo: Jinan Nenghua real products

The most common sizing mistake for pulse power supplies is mixing up average current and peak current — quoting by average, running by peak, and tripping on over-temperature soon after. This article walks through the conversions with concrete numbers.

One rule: size semiconductors by peak, cooling by average

Inside the supply, power devices carry the peak current during each pulse, so the device rating follows the peak. Heat, however, accumulates with the average current, so the cooling system follows the average. Mixing the two leads either to nuisance trips or to chronic over-heating.

The conversion, with examples

Average current = peak current x duty cycle; peak current required = average current / duty cycle.

Process (average current)Duty cyclePeak requiredNote
100 A50%200 ATypical single-pulse plating
100 A30%About 333 ALower duty cycle, higher peak
100 A10%1000 AConfirm peak capability early

Process sheets usually quote average current, while "max output" on a datasheet often means peak. Aligning the two before requesting a quote avoids most sizing disputes.

Voltage side: three things

Control features

Independent adjustment of frequency, duty cycle and peak current separates a programmable pulse power supply from a basic adjustable unit. Check program steps, timed reversal and RS485 protocols against your line requirements. Compare the adjustable pulse power supply and the precision pulse constant-current source, or browse the pulse power supply category.

Related Articles

All News

Frequently Asked Questions

One rule: size semiconductors by peak, cooling by average?
Inside the supply, power devices carry the peak current during each pulse, so the device rating follows the peak. Heat, however, accumulates with the average current, so the cooling system follows the
The conversion, with examples?
Average current = peak current x duty cycle; peak current required = average current / duty cycle. Process (average current)Duty cyclePeak requiredNote 100 A50%200 ATypical single-pulse plating 100 A3
Voltage side: three things?
Cable drop: at high current and low voltage, a few meters of cable cost several volts; the voltage at the load is what counts. Transient headroom: ignition and load steps spike the current; loop respo
Control features?
Independent adjustment of frequency, duty cycle and peak current separates a programmable pulse power supply from a basic adjustable unit. Check program steps, timed reversal and RS485 protocols again