Battery Charge and Discharge Tester / Vehicle-Mounted Battery Charge and Discharge Tester / Compact Battery Charge and Discharge Tester from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Battery Charge and Discharge Tester and its series applications, with engineering customisation to load profile, process requirements and site conditions.
A bidirectional power supply is a power electronic unit in which energy can flow both ways between the grid side and the load side. In the forward direction it converts an AC or DC input into the voltage and current the load needs; in the reverse direction it returns energy from the load (battery, motor, PV string or device under test) to the grid or DC bus instead of dissipating it in a resistor. Compared with the traditional single-direction supply plus dummy load, a bidirectional unit recovers more than 80% of the discharge energy and cuts the heat load and distribution capacity of a test bay to under a third.
The unit comprises an AC/DC active front end, a bidirectional DC/DC stage, a digital control platform and a protection and monitoring unit. The AC/DC stage uses IGBT or SiC PWM rectification (AFE) for four-quadrant operation with actively controlled power factor and current waveform; the DC/DC stage uses a dual active bridge (DAB), LLC/CLLC resonance, four-switch Buck-Boost or a three-level half bridge depending on voltage ratio and isolation requirements. The two stages are coupled through the DC bus, whose stability governs how smoothly the direction changes.
In practical Battery Charge and Discharge Tester installations the unit must hold its output stable against load impedance variation, ambient temperature swings and continuous duty, so device derating, thermal margin and protection thresholds all carry reserve.
Every unit is full-load burned in and waveform tested before dispatch, with a test report and wiring diagram supplied for acceptance and maintenance.
Four-quadrant operation is the core of bidirectional capability. Classified by the phase relation between voltage vector u and current vector i: in-phase current means rectification (absorbing active power), anti-phase means active inversion (returning active power), and quadrature means reactive compensation. Decoupled dq control sets active current id and reactive current iq independently, allowing continuous adjustment of power factor from -1 to +1, which is why a bidirectional unit can act as a load, as a source and as a reactive generator.
The AC/DC topology determines efficiency and harmonic level. A two-level voltage-source PWM rectifier is simple and suits 380 V grids and buses below 800 V; T-type and NPC three-level topologies halve device voltage stress and raise the switching harmonics, allowing filter volume to shrink by 30%–40%; the Vienna rectifier uses a three-level boost structure with one switch per phase for high power density in 10–100 kW modular units. At 8–20 kHz switching, grid current THD stays below 5% with power factor above 0.99.
The bidirectional DC/DC stage is chosen by isolation requirement. Where galvanic isolation is needed a dual active bridge is used: two full bridges coupled through a high-frequency transformer, with power magnitude and direction set by the phase shift φ, P = n·U1·U2·φ(π-|φ|)/(2π²·f·L), so a positive shift transfers forward and a negative shift reverse with symmetrical current stress. Bidirectional LLC/CLLC operation must satisfy the gain curve in both directions, so the resonant point is placed near the rated operating point. Without isolation, a four-switch Buck-Boost transitions seamlessly between step-up and step-down at efficiency up to 98%.
Control uses a voltage outer loop and current inner loop shared by both directions, switching only the sign of the reference and the limit direction, so no retuning is needed when the direction changes. In grid-tied mode a phase-locked loop tracks the grid, with software PLL more robust than zero-crossing detection under distortion and frequency drift; in island mode the unit becomes a voltage source and droop control (P-f, Q-V) shares power between parallel units without communication. On/off-grid transfer typically completes within 10 ms, with UPS or flywheel ride-through for critical loads.
The key constraints on regeneration are grid current quality and anti-islanding. At high return power the grid current must stay below 5% THD and above 0.99 power factor, otherwise upstream protection may trip or neighbouring equipment may be disturbed; anti-islanding protection (active frequency shift or impedance measurement) and low-voltage ride-through are required so the unit exits along a defined curve rather than dropping off suddenly. Where grid export is not permitted, the unit can return to a DC bus or dissipate through a brake unit to avoid bus overvoltage.
The digital control platform uses a DSP for the main control loop and an FPGA for high-speed timing and multi-channel sampling, exchanging data over a parallel bus. Current and voltage are sensed with isolated amplifiers or Hall sensors, whose sampling rate and resolution set the upper limit of loop bandwidth. Voltage and current loop crossover frequencies are set to one third to one fifth of the load time constant, balancing response and stability. Parameters can be read, written and backed up from the host computer for batch replication.
Design and testing follow the GB/T 3859 semiconductor converter standard, GB 17625 harmonic limits, GB/T 2423 environmental test series and IEC 61000 immunity requirements; export models additionally meet the relevant CE or UL clauses. Factory tests typically cover insulation resistance and withstand voltage, full-load temperature rise, efficiency and power factor, ripple and regulation accuracy, and protection trip values, with per-unit records kept for traceability.
Main features:
| Model | Battery Charge and Discharge Tester / Vehicle-Mounted Battery Charge and Discharge Tester / Compact Battery Charge and Discharge Tester |
|---|---|
| Category | Battery Charge and Discharge Tester series |
| Rated power | 5 kW–1 MW (single unit or parallel) |
| Voltage range | AC 380 V ±15% / DC 0–800 V (extendable to 1500 V) |
| Current range | 0–100% rated, continuous in both directions |
| Efficiency | ≥95% regenerating / ≥96% rectifying |
| Power factor | Continuously adjustable -1 to +1, THD ≤5% |
| Related ratings | Customized to application (Battery Charge and Discharge Tester series) |
| Cooling | Water-cooled / air-cooled by power class |
| Protection | Overvoltage, overcurrent, short circuit, overtemperature, phase loss, interlock |
| Communication | RS485 Modbus / Ethernet / analogue (optional) |
Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.
Typical applications of Battery Charge and Discharge Tester / Vehicle-Mounted Battery Charge and Discharge Tester / Compact Battery Charge and Discharge Tester include:
First decide whether grid export is required: where permitted, choose a model with anti-islanding and interconnection protection, since return efficiency and current quality drive the savings; where not permitted, choose DC bus return or brake dissipation.
Define the required transfer time: 10 ms is adequate for most tests, while motor back-to-back and on/off-grid transfer may need under 4 ms, which sets the bus capacitance and control bandwidth.
When paralleling units or building test cabinets, check total return power against the distribution transformer rating; return power should not exceed 30% of the upstream transformer capacity, and upstream protection settings must be verified.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.
If the local grid fluctuates or large equipment starts frequently, verify the input undervoltage and overvoltage protection range and the auto-recovery strategy.
Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.
High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.
Fault diagnosis and predictive maintenance rely on comprehensive monitoring points. The unit continuously acquires bus voltage, output current, device temperature, coolant flow and fan speed, triggering alarms or derating according to severity and storing fault codes, timestamps and key waveforms in non-volatile memory. Host software exports historical curves and estimates remaining life from accumulated operating hours and thermal cycles, turning corrective maintenance into planned maintenance.