Pulse Power Supply / Micro-arc Oxidation Pulse Power Supply / AC Pulse Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Pulse Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.
This series is a pulse power platform for electrochemical, plasma, laser-pumping and materials-processing applications. Instead of a continuous DC output, energy is first accumulated in a storage element and then released into the load in a controlled time sequence, so a peak current or voltage tens of times higher than the average can be obtained at moderate average power. The design is centred on pulse waveform fidelity (rise time, overshoot, top droop, jitter) and long-term repeatability.
The unit consists of a storage stage, a switching stage, a waveform-shaping network, a digital timing controller and a measurement feedback loop. Capacitive or inductive storage is selected according to load behaviour; IGBT, SiC MOSFET, spark gap or thyratron switches are used depending on voltage class and repetition rate; low-inductance busbars, snubber capacitors and matching resistors suppress overshoot and ringing.
For the surge loads and frequent start-stop duty typical of Pulse Power Supply, soft start, current limiting and overload recovery are specifically tuned to avoid nuisance tripping.
Modular construction allows power units, control boards and fans to be replaced independently, with common spares reducing lifetime maintenance cost.
The energy relationship sets the design boundaries. For capacitive storage the single-pulse energy is E = ½CU², and the average power is P_avg = E·f = P_peak·D, where f is the repetition rate and D the duty cycle. Peak and average power may therefore differ by one to two orders of magnitude: a 1 MW peak at 1% duty corresponds to only 10 kW average, yet the storage capacitors, switches and busbars must still be rated for the peak current while the cooling is sized for the average loss. Both boundaries must be checked during selection.
Waveform parameters determine process outcome. The rise time tr and fall time tf are limited by the stray inductance Lσ of the commutation loop, approximately tr ≈ 2.2·Lσ·I/U. An interleaved laminated busbar reduces Lσ below 20 nH, and with snubber capacitors mounted close to the switches a rise time below 50 ns can be achieved at hundreds of amperes. Overshoot is kept within 5% by adequate damping. Top droop reflects the voltage drop of the storage capacitor during the pulse, ΔU = I·tw/C, so capacitors must be selected by energy rather than capacitance alone at high duty cycle.
Bipolar and alternating outputs are implemented with H-bridge or full-bridge topologies, with independent programming of positive and negative pulse width and amplitude. Bipolar pulses suppress charge accumulation and unidirectional polarisation in plating and anodising, giving more uniform film stress; in plasma cleaning and sputtering they suppress target poisoning and arcing. Alternating mode reduces electrode polarisation and stabilises the machining gap in electrochemical machining.
Nanosecond high-voltage pulses follow a different route. A Marx generator charges capacitors in parallel and discharges them in series, giving an output of roughly the stage count times the charging voltage. A Blumlein pulse-forming line folds the energy in a transmission line, with a pulse width of about twice the line length divided by the propagation velocity. A PFN shapes the pulse with an LC ladder network to approximate a square wave on the load. All three rely on fast-closing gas or semiconductor switches and place extreme demands on insulation and compactness.
Closed-loop control provides constant-current, constant-voltage and constant-power modes using shunts or Rogowski coils for sensing. In pulsed operation the error-amplifier bandwidth must cover five to ten times the pulse fundamental frequency, otherwise the amplitude drifts with load within the pulse. A DSP computes the PID loop and outputs PWM, while an FPGA handles nanosecond timing and multi-channel synchronisation, allowing phase differences below 1° between channels.
EMC performance depends on the combination of filtering, shielding and grounding. Input common-mode and differential-mode filter networks suppress conducted interference, snubber capacitors and RC networks reduce device dv/dt, and the enclosure uses continuous welding or conductive gaskets to maintain shielding integrity. Grounding follows single-point practice with separate power and signal grounds, shielded layers grounded at one end to avoid ground loops, and twisted shielded signal cables routed separately from power cables.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.
Main features:
| Model | Pulse Power Supply / Micro-arc Oxidation Pulse Power Supply / AC Pulse Power Supply |
|---|---|
| Category | Pulse Power Supply series |
| Peak output voltage | 0.5–200 kV (model dependent) |
| Peak output current | 10 A–20 kA (model dependent) |
| Repetition rate | Single shot to 1 MHz |
| Pulse width | 50 ns–100 ms, continuously adjustable |
| Duty cycle | 0.01%–50% (up to 100% for continuous models) |
| Related ratings | Customized to application (Pulse Power Supply series) |
| Cooling | Water-cooled / air-cooled by power class |
| Protection | Overvoltage, overcurrent, short circuit, overtemperature, phase loss, interlock |
| Communication | RS485 Modbus / Ethernet / analogue (optional) |
Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.
Typical applications of Pulse Power Supply / Micro-arc Oxidation Pulse Power Supply / AC Pulse Power Supply include:
First define both peak and average boundaries: determine peak current or voltage and pulse width from the process, convert to average power through the duty cycle, and use the two values for device rating and thermal design respectively.
Second, characterise the load impedance: resistive, capacitive, inductive and non-linear loads carry different overshoot and back-feed risks; inductive loads require a freewheeling path or energy-recovery channel, otherwise the L·di/dt at turn-off will destroy the switches.
Fifth, confirm interfaces and interlocks: trigger input and output levels, fibre-optic synchronisation, Modbus/TCP or Ethernet to the host computer, together with safety door interlocks and the emergency-stop loop.
Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.
When several units are installed together, calculate the total heat dissipation and ventilation of the room, adding exhaust or a chiller if required.
Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.
Thermal design determines whether the unit can run at full load continuously. Air-cooled models use zoned airflow with front-to-rear heatsink layout, fin spacing matched to air velocity to reduce pressure drop. Water-cooled models use a cold plate with independent channels, thermal grease or phase-change material to lower contact resistance, and outlet temperature and flow sensors. Overall thermal resistance is calculated for the worst case of maximum ambient, full load and half-blocked filters.
Wide-bandgap devices significantly shift the power-density boundary. SiC MOSFETs have about ten times the breakdown field of silicon, so the drift layer is thinner and on-resistance lower at the same rating. With switching frequencies above 40 kHz, magnetic components shrink by more than half and efficiency improves by one to two percentage points. The trade-off is higher dv/dt and di/dt, which place stricter demands on gate drivers, busbars and filtering.
Fault diagnosis and predictive maintenance rely on comprehensive monitoring points. The unit continuously acquires bus voltage, output current, device temperature, coolant flow and fan speed, triggering alarms or derating according to severity and storing fault codes, timestamps and key waveforms in non-volatile memory. Host software exports historical curves and estimates remaining life from accumulated operating hours and thermal cycles, turning corrective maintenance into planned maintenance.