Inverter Power Supply / High-Efficiency Inverter Power Supply / Off-Grid Inverter Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Inverter Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.
A bidirectional power supply is a power electronic unit in which energy can flow both ways between the grid side and the load side. In the forward direction it converts an AC or DC input into the voltage and current the load needs; in the reverse direction it returns energy from the load (battery, motor, PV string or device under test) to the grid or DC bus instead of dissipating it in a resistor. Compared with the traditional single-direction supply plus dummy load, a bidirectional unit recovers more than 80% of the discharge energy and cuts the heat load and distribution capacity of a test bay to under a third.
The unit comprises an AC/DC active front end, a bidirectional DC/DC stage, a digital control platform and a protection and monitoring unit. The AC/DC stage uses IGBT or SiC PWM rectification (AFE) for four-quadrant operation with actively controlled power factor and current waveform; the DC/DC stage uses a dual active bridge (DAB), LLC/CLLC resonance, four-switch Buck-Boost or a three-level half bridge depending on voltage ratio and isolation requirements. The two stages are coupled through the DC bus, whose stability governs how smoothly the direction changes.
For Inverter Power Supply site requirements the enclosure separates power, control and cabling compartments, so routine maintenance does not require a full shutdown.
Remote diagnostics and parameter backup allow fault records to be read over the communication interface, shortening on-site troubleshooting.
Four-quadrant operation is the core of bidirectional capability. Classified by the phase relation between voltage vector u and current vector i: in-phase current means rectification (absorbing active power), anti-phase means active inversion (returning active power), and quadrature means reactive compensation. Decoupled dq control sets active current id and reactive current iq independently, allowing continuous adjustment of power factor from -1 to +1, which is why a bidirectional unit can act as a load, as a source and as a reactive generator.
The AC/DC topology determines efficiency and harmonic level. A two-level voltage-source PWM rectifier is simple and suits 380 V grids and buses below 800 V; T-type and NPC three-level topologies halve device voltage stress and raise the switching harmonics, allowing filter volume to shrink by 30%–40%; the Vienna rectifier uses a three-level boost structure with one switch per phase for high power density in 10–100 kW modular units. At 8–20 kHz switching, grid current THD stays below 5% with power factor above 0.99.
The bidirectional DC/DC stage is chosen by isolation requirement. Where galvanic isolation is needed a dual active bridge is used: two full bridges coupled through a high-frequency transformer, with power magnitude and direction set by the phase shift φ, P = n·U1·U2·φ(π-|φ|)/(2π²·f·L), so a positive shift transfers forward and a negative shift reverse with symmetrical current stress. Bidirectional LLC/CLLC operation must satisfy the gain curve in both directions, so the resonant point is placed near the rated operating point. Without isolation, a four-switch Buck-Boost transitions seamlessly between step-up and step-down at efficiency up to 98%.
Control uses a voltage outer loop and current inner loop shared by both directions, switching only the sign of the reference and the limit direction, so no retuning is needed when the direction changes. In grid-tied mode a phase-locked loop tracks the grid, with software PLL more robust than zero-crossing detection under distortion and frequency drift; in island mode the unit becomes a voltage source and droop control (P-f, Q-V) shares power between parallel units without communication. On/off-grid transfer typically completes within 10 ms, with UPS or flywheel ride-through for critical loads.
The key constraints on regeneration are grid current quality and anti-islanding. At high return power the grid current must stay below 5% THD and above 0.99 power factor, otherwise upstream protection may trip or neighbouring equipment may be disturbed; anti-islanding protection (active frequency shift or impedance measurement) and low-voltage ride-through are required so the unit exits along a defined curve rather than dropping off suddenly. Where grid export is not permitted, the unit can return to a DC bus or dissipate through a brake unit to avoid bus overvoltage.
Device derating and lifetime are key constraints of this series. Electrolytic capacitor life roughly halves for every 10 °C rise, so selection checks both ripple current and case temperature, and capacitors are placed away from heat sources and airflow dead zones. IGBT and SiC modules are derated to a junction temperature below 125 °C (150 °C for SiC), with short-circuit withstand time and thermal cycling capability verified to keep margin under frequent start-stop and load swings.
Fault diagnosis and predictive maintenance rely on comprehensive monitoring points. The unit continuously acquires bus voltage, output current, device temperature, coolant flow and fan speed, triggering alarms or derating according to severity and storing fault codes, timestamps and key waveforms in non-volatile memory. Host software exports historical curves and estimates remaining life from accumulated operating hours and thermal cycles, turning corrective maintenance into planned maintenance.
Main features:
| Model | Inverter Power Supply / High-Efficiency Inverter Power Supply / Off-Grid Inverter Power Supply |
|---|---|
| Category | Inverter Power Supply series |
| Rated power | 5 kW–1 MW (single unit or parallel) |
| Voltage range | AC 380 V ±15% / DC 0–800 V (extendable to 1500 V) |
| Current range | 0–100% rated, continuous in both directions |
| Efficiency | ≥95% regenerating / ≥96% rectifying |
| Power factor | Continuously adjustable -1 to +1, THD ≤5% |
| Related ratings | Customized to application (Inverter Power Supply series) |
| Cooling | Water-cooled / air-cooled by power class |
| Protection | Overvoltage, overcurrent, short circuit, overtemperature, phase loss, interlock |
| Communication | RS485 Modbus / Ethernet / analogue (optional) |
Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.
Typical applications of Inverter Power Supply / High-Efficiency Inverter Power Supply / Off-Grid Inverter Power Supply include:
First decide whether grid export is required: where permitted, choose a model with anti-islanding and interconnection protection, since return efficiency and current quality drive the savings; where not permitted, choose DC bus return or brake dissipation.
Size by the maximum voltage and current of the device under test with 20%–30% margin. For battery testing check the minimum discharge voltage, since operation below the constant-power region must be converted to current capability in the constant-current region.
Confirm interfaces and protocols: CAN, RS485, Modbus/TCP, SCPI programming, waveform editing and data logging, plus the BMS communication point list, to avoid additional engineering.
Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.
For projects integrating with an existing control system, confirm the communication protocol details and point list before contract to avoid rework.
Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.
EMC performance depends on the combination of filtering, shielding and grounding. Input common-mode and differential-mode filter networks suppress conducted interference, snubber capacitors and RC networks reduce device dv/dt, and the enclosure uses continuous welding or conductive gaskets to maintain shielding integrity. Grounding follows single-point practice with separate power and signal grounds, shielded layers grounded at one end to avoid ground loops, and twisted shielded signal cables routed separately from power cables.
Wide-bandgap devices significantly shift the power-density boundary. SiC MOSFETs have about ten times the breakdown field of silicon, so the drift layer is thinner and on-resistance lower at the same rating. With switching frequencies above 40 kHz, magnetic components shrink by more than half and efficiency improves by one to two percentage points. The trade-off is higher dv/dt and di/dt, which place stricter demands on gate drivers, busbars and filtering.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.