Anodizing Power Supply / Aluminum-alloy Oxidation Power Supply / Anti-corrosion Oxidation Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Anodizing Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.
This series is a dedicated DC supply for electroplating, anodising, electrophoresis and surface treatment. Plating demands concentrate on three points: low ripple, stable current and programmable reverse or pulse capability for throwing power in blind holes and complex parts.
The unit uses either a high-frequency switching topology with IGBT full bridge, high-frequency transformer isolation and fast-recovery rectification, or a thyristor phase-controlled topology, with low-inductance output filtering and current sensing. The controller offers constant-current, constant-voltage, reverse and pulse modes with multi-step profiles.
In practical Anodizing Power Supply installations the unit must hold its output stable against load impedance variation, ambient temperature swings and continuous duty, so device derating, thermal margin and protection thresholds all carry reserve.
Every unit is full-load burned in and waveform tested before dispatch, with a test report and wiring diagram supplied for acceptance and maintenance.
Coating quality depends directly on current-density distribution. Too low a density deposits slowly and loosely; too high burns and roughens the deposit. Ripple makes the instantaneous current density swing widely, coarsening grains and reducing brightness, so plating supplies usually require ripple ≤1%, ≤0.5% for hard chrome and precision work, and even ≤0.1% for high-end decorative coatings.
Periodic reverse plating alternates the current direction, depositing in the forward cycle and dissolving in the reverse cycle. The reverse pulse dissolves protrusions and impurities, levelling the deposit and improving throwing power in blind and deep holes. Typical ratios are 10–30 s forward with 0.5–3 s reverse, programmable per process.
Pulse plating uses high peak current density, short pulse width and low duty cycle. The high peak raises nucleation rate and refines grains, while the interval restores ion concentration and reduces concentration polarisation, producing dense coatings with low porosity. Typical parameters are 10–100 A/dm² peak, 0.1–10 ms pulse width and 10%–30% duty cycle.
Hard chrome plating is a severe duty: 30–60 A/dm², 6–12 V, 50–60 °C bath temperature, requiring continuous full-load capability and a good current rise rate. PCB plating instead demands very high throwing power, typically using pulse or reverse supplies with strong jet agitation.
In terms of topology, high-frequency switching above 20 kHz with a high-frequency transformer pushes ripple into an easily filtered band, reaches efficiency above 90% and reduces volume and weight to a fraction of an equivalent phase-controlled unit. Phase-controlled units are simple and tolerant of overload, and suit very high current hard-chrome duty.
Thermal design determines whether the unit can run at full load continuously. Air-cooled models use zoned airflow with front-to-rear heatsink layout, fin spacing matched to air velocity to reduce pressure drop. Water-cooled models use a cold plate with independent channels, thermal grease or phase-change material to lower contact resistance, and outlet temperature and flow sensors. Overall thermal resistance is calculated for the worst case of maximum ambient, full load and half-blocked filters.
Design and testing follow the GB/T 3859 semiconductor converter standard, GB 17625 harmonic limits, GB/T 2423 environmental test series and IEC 61000 immunity requirements; export models additionally meet the relevant CE or UL clauses. Factory tests typically cover insulation resistance and withstand voltage, full-load temperature rise, efficiency and power factor, ripple and regulation accuracy, and protection trip values, with per-unit records kept for traceability.
Main features:
| Model | Anodizing Power Supply / Aluminum-alloy Oxidation Power Supply / Anti-corrosion Oxidation Power Supply |
|---|---|
| Category | Anodizing Power Supply series |
| Output DC voltage | 0–24 V (up to 36 V for hard chrome) |
| Output DC current | 0–50 kA (model dependent) |
| Ripple factor | ≤1% (≤0.1% for precision models) |
| Reverse cycle | Forward 1–999 s / reverse 0.1–99 s, programmable |
| Efficiency | ≥90% (high-frequency models) |
| Related ratings | Customized to application (Anodizing Power Supply series) |
| Cooling | Water-cooled / air-cooled by power class |
| Protection | Overvoltage, overcurrent, short circuit, overtemperature, phase loss, interlock |
| Communication | RS485 Modbus / Ethernet / analogue (optional) |
Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.
Typical applications of Anodizing Power Supply / Aluminum-alloy Oxidation Power Supply / Anti-corrosion Oxidation Power Supply include:
Size the unit by total bath current: current density times total workpiece area with 1.2 times margin. For hard chrome and large parts, peak current capability matters more than average power.
Choose the ripple class by process: ≤1% for general decorative plating, ≤0.5% for hard chrome and precision work, ≤0.1% for optical and high-end decorative coatings.
Confirm bath corrosivity and installation: acid-mist sites need corrosion-resistant models with isolated air ducts, and the supply should be placed close to the bath.
Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.
For projects integrating with an existing control system, confirm the communication protocol details and point list before contract to avoid rework.
Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.
High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.
Output filtering and ripple control involve a trade-off between size, cost and performance. A larger inductor reduces ripple but slows dynamic response and increases copper loss; a higher switching frequency shrinks the inductor but raises switching loss and EMI. In practice, interleaved multiphase operation raises the effective ripple frequency, LC and pi filters suppress high-frequency components, and low-ESR capacitors at the output improve transient response.