Customized Power Supply / Wide-Temperature Customized Power Supply / High-Current Customized Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Customized Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.

Customized Power Supply / Wide-Temperature Customized Power Supply / High-Current Customized Power Supply manufacturer-direct supply with custom engineering, selection calculation, drawing confirmation and on-site commissioning.
Contact Us 0531-68684888

Product Introduction

This series is a voltage-class family of DC power supplies covering 24 V, 48 V, 110 V and 220 V industrial and power-operation levels, 750 V, 1000 V and 1500 V storage and charging platform levels, and high-voltage DC duties from 3000 V up to 35 kV. Each class carries its own device ratings, insulation distances and topology, with efficiency, ripple, protection and communication tailored to the application.

The unit comprises an input rectifier or PFC stage, an isolated or non-isolated DC/DC stage, output filtering, sensing and digital control, protection and communication, and cooling. Low-voltage high-current models use synchronous rectification and multiphase paralleling to cut conduction loss; high-voltage models use three-level or multilevel structures to reduce device stress; stringent insulation duties use dry-type or oil-immersed construction with partial-discharge control.

For the surge loads and frequent start-stop duty typical of Customized Power Supply, soft start, current limiting and overload recovery are specifically tuned to avoid nuisance tripping.

Every unit is full-load burned in and waveform tested before dispatch, with a test report and wiring diagram supplied for acceptance and maintenance.

Working Principle

Voltage class sets device and insulation selection. A 220 V DC bus can use 650 V devices, a 750 V bus typically uses 1200 V devices, and a 1500 V bus uses 1700 V or 3300 V devices with three-level topologies that halve the per-device stress. Each step up in voltage raises creepage distance, clearance and tracking-index requirements, and changes enclosure size and thermal design.

Typical topologies use a two-stage structure of PFC followed by an LLC resonant or phase-shifted full-bridge converter. The front stage shapes the input current into a sinusoid and provides a regulated bus, while the rear stage provides isolation and regulation through a high-frequency transformer. LLC operating near resonance achieves zero-voltage turn-on on the primary and zero-current turn-off on the secondary rectifiers, reaching efficiency above 96%. For medium and high power with wide voltage range, the dual active bridge (DAB) provides bidirectional energy flow and wide regulation through phase-shift control.

The 1500 V DC platform is now mainstream for storage and PV. Compared with 1000 V systems the current is one third lower at the same power, cutting line loss and copper usage. However DC arcs are harder to extinguish, so dedicated DC breakers, fuses and arc-fault detection are mandatory, together with reverse-polarity protection and a visible isolation point for maintenance. SiC devices raise switching frequency to 40–100 kHz, pushing converter efficiency above 98% and shrinking magnetic components.

Ripple, accuracy and dynamic response are the three basic performance metrics. Ripple is set by switching frequency and output filtering, typically ≤1% for industrial models and ≤0.1% for test and research models. Voltage accuracy is typically ±0.5%, reaching ±0.05% in high-precision models. Dynamic response is measured as the recovery time to ±1% after a load step, with fast models below 1 ms.

Protection and monitoring must address overvoltage, overcurrent, short circuit, reverse polarity, insulation degradation and DC arcing. An insulation monitoring device (IMD) injects a low-frequency signal or measures the asymmetry of positive and negative rail voltages to earth. DC breakers must extinguish arcs and break in both directions. Charging and storage systems also need pre-charge circuits to limit inrush and protect bus capacitors.

Thermal design determines whether the unit can run at full load continuously. Air-cooled models use zoned airflow with front-to-rear heatsink layout, fin spacing matched to air velocity to reduce pressure drop. Water-cooled models use a cold plate with independent channels, thermal grease or phase-change material to lower contact resistance, and outlet temperature and flow sensors. Overall thermal resistance is calculated for the worst case of maximum ambient, full load and half-blocked filters.

Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.

Key Features

  • Complete voltage range: 24/48/110/220/336/400/750/1000/1500/3000 V and up to 35 kV, matched to the application.
  • High-efficiency topologies: LLC resonant, phase-shifted full bridge and DAB, with full-load efficiency ≥96% and up to 98% with SiC.
  • High accuracy: voltage regulation ±0.5% (±0.05% optional), ripple ≤1% (≤0.1% optional).
  • DC safety design: insulation monitoring, arc-fault detection, reverse-polarity protection, pre-charge limiting and a visible isolation point.
  • Cabinet temperature, humidity and dust status are monitored, giving early warning instead of an abrupt trip.
  • Structural parts are phosphated and powder coated with stainless fasteners for humid and corrosive workshops.

Main features:

Technical Parameters

ModelCustomized Power Supply / Wide-Temperature Customized Power Supply / High-Current Customized Power Supply
CategoryCustomized Power Supply series
Output voltage range24 V–35 kV (voltage-class family)
Output power0.5 kW–2 MW (parallel expandable)
Voltage accuracy±0.5% (±0.05% optional)
Ripple factor≤1% (≤0.1% optional)
Full-load efficiency≥96% (≥98% with SiC)
Related ratingsCustomized to application (Customized Power Supply series)
CoolingWater-cooled / air-cooled by power class
ProtectionOvervoltage, overcurrent, short circuit, overtemperature, phase loss, interlock
CommunicationRS485 Modbus / Ethernet / analogue (optional)

Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.

Applications

  • Storage and PV: battery cluster supply, auxiliary supplies for storage PCS, MPPT feeding and combiner-box supplies.
  • Charging and battery swap: DC charging modules, charging stacks, liquid-cooled ultra-fast charging and V2G bidirectional conversion.
  • Data centres and telecom: 240/336/400/480 V HVDC feeding, DC column cabinets and server power supplies.
  • Power operation supplies: 110/220 V DC panels, substation operation supplies and relay protection supplies.
  • Rail transit and marine: 750/1500 V traction supply, vehicle auxiliary supplies and shore-side DC distribution.
  • Industry and test: plating, electrolysis, electrostatic precipitation, device burn-in and laboratory DC sources.

Typical applications of Customized Power Supply / Wide-Temperature Customized Power Supply / High-Current Customized Power Supply include:

Selection Guide

Determine voltage class and power from the system bus voltage and maximum current, then check overload and surge capability against the load type (resistive, capacitive, motor or battery).

Choose the topology by efficiency and size requirements: LLC or DAB for efficiency-critical high power, DAB for wide range and bidirectional duty, and phase-shifted full bridge for cost-sensitive medium power.

Determine the construction by insulation and safety requirements: high-voltage duties need creepage and clearance verification, sometimes oil-immersed or gas-insulated construction with partial-discharge testing.

Output filtering and ripple control involve a trade-off between size, cost and performance. A larger inductor reduces ripple but slows dynamic response and increases copper loss; a higher switching frequency shrinks the inductor but raises switching loss and EMI. In practice, interleaved multiphase operation raises the effective ripple frequency, LC and pi filters suppress high-frequency components, and low-ESR capacitors at the output improve transient response.

When several units are installed together, calculate the total heat dissipation and ventilation of the room, adding exhaust or a chiller if required.

Operation & Maintenance

Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.

EMC performance depends on the combination of filtering, shielding and grounding. Input common-mode and differential-mode filter networks suppress conducted interference, snubber capacitors and RC networks reduce device dv/dt, and the enclosure uses continuous welding or conductive gaskets to maintain shielding integrity. Grounding follows single-point practice with separate power and signal grounds, shielded layers grounded at one end to avoid ground loops, and twisted shielded signal cables routed separately from power cables.

Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.

High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.

FAQ

What are the practical benefits of 1500 V DC over 1000 V?
At the same power the bus current is about one third lower, line loss falls with the square of current, and cable and busbar usage is reduced, lowering cost and footprint. The trade-off is higher device voltage rating, DC arc extinction and insulation monitoring requirements, with dedicated DC breakers and arc-fault detection.
How should LLC and phase-shifted full bridge be chosen?
LLC is most efficient near resonance with low EMI and suits applications with limited output voltage variation. Phase-shifted full bridge maintains good performance over a wide range with simple control. If bidirectional energy flow is required, a DAB should be selected.
Why can't AC earth-leakage protection replace insulation monitoring in DC systems?
AC leakage protection cannot identify simultaneous insulation degradation of both DC rails to earth, and DC arcs have no natural zero crossing, so they do not self-extinguish. Dedicated insulation monitoring devices continuously measure insulation resistance to earth, combined with DC breakers and arc-fault detection.
What are the installation requirements for Customized Power Supply / Wide-Temperature Customized Power Supply / High-Current Customized Power Supply?
Install in a well-ventilated area free of conductive dust and corrosive gas, with ambient temperature from -10 to 40 °C (up to 50 °C for water-cooled models) and at least 800 mm maintenance clearance front and rear. Water-cooled models require circulating water at the specified pressure and flow with inlet temperature not above 32 °C. Ground resistance should be below 4 ohm and power and signal cables should be routed in separate trays.
What is the lead time and customisation scope for Customized Power Supply / Wide-Temperature Customized Power Supply / High-Current Customized Power Supply?
Standard ratings are delivered within the agreed period after contract effectiveness. Output voltage, current, communication protocol, cabinet dimensions and protection class can all be customised; custom models require load characteristics, operating environment and interface requirements for the electrical and mechanical design.