High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply

Product Center / Anodizing Power Supply

High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply - Anodizing Power Supply

High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for High-frequency Oxidation Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.

High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply manufacturer-direct supply with custom engineering, selection calculation, drawing confirmation and on-site commissioning.
Contact Us 0531-68684888

Product Introduction

This series is a dedicated DC supply for electroplating, anodising, electrophoresis and surface treatment. Plating demands concentrate on three points: low ripple, stable current and programmable reverse or pulse capability for throwing power in blind holes and complex parts.

The unit uses either a high-frequency switching topology with IGBT full bridge, high-frequency transformer isolation and fast-recovery rectification, or a thyristor phase-controlled topology, with low-inductance output filtering and current sensing. The controller offers constant-current, constant-voltage, reverse and pulse modes with multi-step profiles.

For the surge loads and frequent start-stop duty typical of High-frequency Oxidation Power Supply, soft start, current limiting and overload recovery are specifically tuned to avoid nuisance tripping.

Modular construction allows power units, control boards and fans to be replaced independently, with common spares reducing lifetime maintenance cost.

Working Principle

Coating quality depends directly on current-density distribution. Too low a density deposits slowly and loosely; too high burns and roughens the deposit. Ripple makes the instantaneous current density swing widely, coarsening grains and reducing brightness, so plating supplies usually require ripple ≤1%, ≤0.5% for hard chrome and precision work, and even ≤0.1% for high-end decorative coatings.

Periodic reverse plating alternates the current direction, depositing in the forward cycle and dissolving in the reverse cycle. The reverse pulse dissolves protrusions and impurities, levelling the deposit and improving throwing power in blind and deep holes. Typical ratios are 10–30 s forward with 0.5–3 s reverse, programmable per process.

Pulse plating uses high peak current density, short pulse width and low duty cycle. The high peak raises nucleation rate and refines grains, while the interval restores ion concentration and reduces concentration polarisation, producing dense coatings with low porosity. Typical parameters are 10–100 A/dm² peak, 0.1–10 ms pulse width and 10%–30% duty cycle.

Hard chrome plating is a severe duty: 30–60 A/dm², 6–12 V, 50–60 °C bath temperature, requiring continuous full-load capability and a good current rise rate. PCB plating instead demands very high throwing power, typically using pulse or reverse supplies with strong jet agitation.

In terms of topology, high-frequency switching above 20 kHz with a high-frequency transformer pushes ripple into an easily filtered band, reaches efficiency above 90% and reduces volume and weight to a fraction of an equivalent phase-controlled unit. Phase-controlled units are simple and tolerant of overload, and suit very high current hard-chrome duty.

Design and testing follow the GB/T 3859 semiconductor converter standard, GB 17625 harmonic limits, GB/T 2423 environmental test series and IEC 61000 immunity requirements; export models additionally meet the relevant CE or UL clauses. Factory tests typically cover insulation resistance and withstand voltage, full-load temperature rise, efficiency and power factor, ripple and regulation accuracy, and protection trip values, with per-unit records kept for traceability.

Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.

Key Features

  • Low ripple: high-frequency switching with multi-stage LC filtering, ripple ≤1% (≤0.1% for precision models).
  • High current accuracy: Hall sensor or shunt with high-resolution ADC, current regulation within 0.5%.
  • Corrosion protection and thermal design: epoxy-coated enclosure and isolated air path for acid mist and humid environments.
  • Complete protection: overcurrent, overvoltage, short circuit, overtemperature, liquid level and rectifier overtemperature protection with alarms.
  • Cabinet temperature, humidity and dust status are monitored, giving early warning instead of an abrupt trip.
  • Structural parts are phosphated and powder coated with stainless fasteners for humid and corrosive workshops.

Main features:

Technical Parameters

ModelHigh-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply
CategoryHigh-frequency Oxidation Power Supply series
Output DC voltage0–24 V (up to 36 V for hard chrome)
Output DC current0–50 kA (model dependent)
Ripple factor≤1% (≤0.1% for precision models)
Reverse cycleForward 1–999 s / reverse 0.1–99 s, programmable
Efficiency≥90% (high-frequency models)
Related ratingsCustomized to application (High-frequency Oxidation Power Supply series)
CoolingWater-cooled / air-cooled by power class
ProtectionOvervoltage, overcurrent, short circuit, overtemperature, phase loss, interlock
CommunicationRS485 Modbus / Ethernet / analogue (optional)

Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.

Applications

  • Decorative and functional plating: chrome, nickel, copper, zinc, silver, gold and alloy plating.
  • Hard chrome and repair plating: hydraulic rods, moulds and rollers.
  • PCB and electronics plating: through-hole plating, connectors and semiconductor lead frames.
  • Anodising: hard anodising of aluminium profiles, micro-arc oxidation and colour anodising.
  • Electrophoretic coating: cathodic and anodic e-coating for automotive and hardware parts.
  • Electropolishing and cleaning: stainless steel polishing, electrochemical deburring and cleaning.

Typical applications of High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply include:

Selection Guide

Select functions by part complexity: reverse or pulse models for deep holes and complex geometry; standard DC models suffice for simple flat parts.

Confirm bath corrosivity and installation: acid-mist sites need corrosion-resistant models with isolated air ducts, and the supply should be placed close to the bath.

Confirm process-management needs: multi-step profiles, recipe storage, throughput statistics and host connectivity determine the controller specification.

Correct installation and commissioning directly affect service life. After positioning, the cabinet is levelled and secured, incoming and outgoing cables are checked for phase sequence and polarity, and power cable cross-sections are chosen for both ampacity and permissible voltage drop. Before energising, insulation resistance is measured and short circuits ruled out; the first start uses soft start or low-voltage trial operation to verify bus establishment, fan direction and communication, then loading proceeds gradually with temperature rise recorded.

For projects integrating with an existing control system, confirm the communication protocol details and point list before contract to avoid rework.

Operation & Maintenance

Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.

High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.

Correct installation and commissioning directly affect service life. After positioning, the cabinet is levelled and secured, incoming and outgoing cables are checked for phase sequence and polarity, and power cable cross-sections are chosen for both ampacity and permissible voltage drop. Before energising, insulation resistance is measured and short circuits ruled out; the first start uses soft start or low-voltage trial operation to verify bus establishment, fan direction and communication, then loading proceeds gradually with temperature rise recorded.

Output filtering and ripple control involve a trade-off between size, cost and performance. A larger inductor reduces ripple but slows dynamic response and increases copper loss; a higher switching frequency shrinks the inductor but raises switching loss and EMI. In practice, interleaved multiphase operation raises the effective ripple frequency, LC and pi filters suppress high-frequency components, and low-ESR capacitors at the output improve transient response.

FAQ

What exactly does high ripple do to the coating?
Ripple swings the instantaneous current density far above and below the average. Peaks burn the deposit and create rough particles while troughs deposit slowly, resulting in coarse grains, lower brightness and higher porosity. For hard chrome and optical coatings, ripple also affects hardness and reflectivity.
When is a reverse-pulse supply necessary?
Reverse supplies are recommended for deep holes, blind holes, complex geometry and any case requiring high throwing power. The reverse pulse dissolves deposits on protrusions and detaches impurities and hydrogen bubbles, evening out current distribution.
What are the advantages of pulse plating over DC plating?
Pulse plating uses a high peak current to raise nucleation rate and refine grains, while the interval restores ion concentration and reduces concentration polarisation, giving denser coatings with lower porosity and lower internal stress. For precious metals it also allows thinner deposits with equivalent performance.
What are the installation requirements for High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply?
Install in a well-ventilated area free of conductive dust and corrosive gas, with ambient temperature from -10 to 40 °C (up to 50 °C for water-cooled models) and at least 800 mm maintenance clearance front and rear. Water-cooled models require circulating water at the specified pressure and flow with inlet temperature not above 32 °C. Ground resistance should be below 4 ohm and power and signal cables should be routed in separate trays.
What is the lead time and customisation scope for High-frequency Oxidation Power Supply / Redundant High-frequency Oxidation Power Supply / Industrial-Grade High-frequency Oxidation Power Supply?
Standard ratings are delivered within the agreed period after contract effectiveness. Output voltage, current, communication protocol, cabinet dimensions and protection class can all be customised; custom models require load characteristics, operating environment and interface requirements for the electrical and mechanical design.
← Electrolysis Power Supply / Parallel Electrolysis Power Supply / Single-Tank Electrolysis Power Supply Induction Heating Power Supply / Water-Cooled Induction Heating Power Supply / Three-Phase Induction Heating Power Supply →