Anodizing Power Supply / Phosphoric-acid Oxidation Power Supply / Oxidation Power Supply Unit from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Anodizing Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.
This series is a dedicated DC supply for electroplating, anodising, electrophoresis and surface treatment. Plating demands concentrate on three points: low ripple, stable current and programmable reverse or pulse capability for throwing power in blind holes and complex parts.
The unit uses either a high-frequency switching topology with IGBT full bridge, high-frequency transformer isolation and fast-recovery rectification, or a thyristor phase-controlled topology, with low-inductance output filtering and current sensing. The controller offers constant-current, constant-voltage, reverse and pulse modes with multi-step profiles.
In practical Anodizing Power Supply installations the unit must hold its output stable against load impedance variation, ambient temperature swings and continuous duty, so device derating, thermal margin and protection thresholds all carry reserve.
Remote diagnostics and parameter backup allow fault records to be read over the communication interface, shortening on-site troubleshooting.
Coating quality depends directly on current-density distribution. Too low a density deposits slowly and loosely; too high burns and roughens the deposit. Ripple makes the instantaneous current density swing widely, coarsening grains and reducing brightness, so plating supplies usually require ripple ≤1%, ≤0.5% for hard chrome and precision work, and even ≤0.1% for high-end decorative coatings.
Periodic reverse plating alternates the current direction, depositing in the forward cycle and dissolving in the reverse cycle. The reverse pulse dissolves protrusions and impurities, levelling the deposit and improving throwing power in blind and deep holes. Typical ratios are 10–30 s forward with 0.5–3 s reverse, programmable per process.
Pulse plating uses high peak current density, short pulse width and low duty cycle. The high peak raises nucleation rate and refines grains, while the interval restores ion concentration and reduces concentration polarisation, producing dense coatings with low porosity. Typical parameters are 10–100 A/dm² peak, 0.1–10 ms pulse width and 10%–30% duty cycle.
Hard chrome plating is a severe duty: 30–60 A/dm², 6–12 V, 50–60 °C bath temperature, requiring continuous full-load capability and a good current rise rate. PCB plating instead demands very high throwing power, typically using pulse or reverse supplies with strong jet agitation.
In terms of topology, high-frequency switching above 20 kHz with a high-frequency transformer pushes ripple into an easily filtered band, reaches efficiency above 90% and reduces volume and weight to a fraction of an equivalent phase-controlled unit. Phase-controlled units are simple and tolerant of overload, and suit very high current hard-chrome duty.
High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.
Correct installation and commissioning directly affect service life. After positioning, the cabinet is levelled and secured, incoming and outgoing cables are checked for phase sequence and polarity, and power cable cross-sections are chosen for both ampacity and permissible voltage drop. Before energising, insulation resistance is measured and short circuits ruled out; the first start uses soft start or low-voltage trial operation to verify bus establishment, fan direction and communication, then loading proceeds gradually with temperature rise recorded.
Main features:
| Model | Anodizing Power Supply / Phosphoric-acid Oxidation Power Supply / Oxidation Power Supply Unit |
|---|---|
| Category | Anodizing Power Supply series |
| Output DC voltage | 0–24 V (up to 36 V for hard chrome) |
| Output DC current | 0–50 kA (model dependent) |
| Ripple factor | ≤1% (≤0.1% for precision models) |
| Reverse cycle | Forward 1–999 s / reverse 0.1–99 s, programmable |
| Efficiency | ≥90% (high-frequency models) |
| Related ratings | Customized to application (Anodizing Power Supply series) |
| Cooling | Water-cooled / air-cooled by power class |
| Protection | Overvoltage, overcurrent, short circuit, overtemperature, phase loss, interlock |
| Communication | RS485 Modbus / Ethernet / analogue (optional) |
Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.
Typical applications of Anodizing Power Supply / Phosphoric-acid Oxidation Power Supply / Oxidation Power Supply Unit include:
Size the unit by total bath current: current density times total workpiece area with 1.2 times margin. For hard chrome and large parts, peak current capability matters more than average power.
Select functions by part complexity: reverse or pulse models for deep holes and complex geometry; standard DC models suffice for simple flat parts.
Confirm process-management needs: multi-step profiles, recipe storage, throughput statistics and host connectivity determine the controller specification.
Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.
If the local grid fluctuates or large equipment starts frequently, verify the input undervoltage and overvoltage protection range and the auto-recovery strategy.
Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.
Fault diagnosis and predictive maintenance rely on comprehensive monitoring points. The unit continuously acquires bus voltage, output current, device temperature, coolant flow and fan speed, triggering alarms or derating according to severity and storing fault codes, timestamps and key waveforms in non-volatile memory. Host software exports historical curves and estimates remaining life from accumulated operating hours and thermal cycles, turning corrective maintenance into planned maintenance.
Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.
Output filtering and ripple control involve a trade-off between size, cost and performance. A larger inductor reduces ripple but slows dynamic response and increases copper loss; a higher switching frequency shrinks the inductor but raises switching loss and EMI. In practice, interleaved multiphase operation raises the effective ripple frequency, LC and pi filters suppress high-frequency components, and low-ESR capacitors at the output improve transient response.