Micro-arc Oxidation Power Supply / Low-Voltage Micro-arc Oxidation Power Supply / Single-Phase Micro-arc Oxidation Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Micro-arc Oxidation Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.
This series is a dedicated DC supply for electroplating, anodising, electrophoresis and surface treatment. Plating demands concentrate on three points: low ripple, stable current and programmable reverse or pulse capability for throwing power in blind holes and complex parts.
The unit uses either a high-frequency switching topology with IGBT full bridge, high-frequency transformer isolation and fast-recovery rectification, or a thyristor phase-controlled topology, with low-inductance output filtering and current sensing. The controller offers constant-current, constant-voltage, reverse and pulse modes with multi-step profiles.
For the surge loads and frequent start-stop duty typical of Micro-arc Oxidation Power Supply, soft start, current limiting and overload recovery are specifically tuned to avoid nuisance tripping.
Every unit is full-load burned in and waveform tested before dispatch, with a test report and wiring diagram supplied for acceptance and maintenance.
Coating quality depends directly on current-density distribution. Too low a density deposits slowly and loosely; too high burns and roughens the deposit. Ripple makes the instantaneous current density swing widely, coarsening grains and reducing brightness, so plating supplies usually require ripple ≤1%, ≤0.5% for hard chrome and precision work, and even ≤0.1% for high-end decorative coatings.
Periodic reverse plating alternates the current direction, depositing in the forward cycle and dissolving in the reverse cycle. The reverse pulse dissolves protrusions and impurities, levelling the deposit and improving throwing power in blind and deep holes. Typical ratios are 10–30 s forward with 0.5–3 s reverse, programmable per process.
Pulse plating uses high peak current density, short pulse width and low duty cycle. The high peak raises nucleation rate and refines grains, while the interval restores ion concentration and reduces concentration polarisation, producing dense coatings with low porosity. Typical parameters are 10–100 A/dm² peak, 0.1–10 ms pulse width and 10%–30% duty cycle.
Hard chrome plating is a severe duty: 30–60 A/dm², 6–12 V, 50–60 °C bath temperature, requiring continuous full-load capability and a good current rise rate. PCB plating instead demands very high throwing power, typically using pulse or reverse supplies with strong jet agitation.
In terms of topology, high-frequency switching above 20 kHz with a high-frequency transformer pushes ripple into an easily filtered band, reaches efficiency above 90% and reduces volume and weight to a fraction of an equivalent phase-controlled unit. Phase-controlled units are simple and tolerant of overload, and suit very high current hard-chrome duty.
Thermal design determines whether the unit can run at full load continuously. Air-cooled models use zoned airflow with front-to-rear heatsink layout, fin spacing matched to air velocity to reduce pressure drop. Water-cooled models use a cold plate with independent channels, thermal grease or phase-change material to lower contact resistance, and outlet temperature and flow sensors. Overall thermal resistance is calculated for the worst case of maximum ambient, full load and half-blocked filters.
EMC performance depends on the combination of filtering, shielding and grounding. Input common-mode and differential-mode filter networks suppress conducted interference, snubber capacitors and RC networks reduce device dv/dt, and the enclosure uses continuous welding or conductive gaskets to maintain shielding integrity. Grounding follows single-point practice with separate power and signal grounds, shielded layers grounded at one end to avoid ground loops, and twisted shielded signal cables routed separately from power cables.
Main features:
| Model | Micro-arc Oxidation Power Supply / Low-Voltage Micro-arc Oxidation Power Supply / Single-Phase Micro-arc Oxidation Power Supply |
|---|---|
| Category | Micro-arc Oxidation Power Supply series |
| Output DC voltage | 0–24 V (up to 36 V for hard chrome) |
| Output DC current | 0–50 kA (model dependent) |
| Ripple factor | ≤1% (≤0.1% for precision models) |
| Reverse cycle | Forward 1–999 s / reverse 0.1–99 s, programmable |
| Efficiency | ≥90% (high-frequency models) |
| Related ratings | Customized to application (Micro-arc Oxidation Power Supply series) |
| Cooling | Water-cooled / air-cooled by power class |
| Protection | Overvoltage, overcurrent, short circuit, overtemperature, phase loss, interlock |
| Communication | RS485 Modbus / Ethernet / analogue (optional) |
Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.
Typical applications of Micro-arc Oxidation Power Supply / Low-Voltage Micro-arc Oxidation Power Supply / Single-Phase Micro-arc Oxidation Power Supply include:
Size the unit by total bath current: current density times total workpiece area with 1.2 times margin. For hard chrome and large parts, peak current capability matters more than average power.
Choose the ripple class by process: ≤1% for general decorative plating, ≤0.5% for hard chrome and precision work, ≤0.1% for optical and high-end decorative coatings.
Confirm bath corrosivity and installation: acid-mist sites need corrosion-resistant models with isolated air ducts, and the supply should be placed close to the bath.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.
Where budget allows, choose one power class higher: the difference in temperature rise and life under continuous full load far outweighs the purchase price.
Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.
Design and testing follow the GB/T 3859 semiconductor converter standard, GB 17625 harmonic limits, GB/T 2423 environmental test series and IEC 61000 immunity requirements; export models additionally meet the relevant CE or UL clauses. Factory tests typically cover insulation resistance and withstand voltage, full-load temperature rise, efficiency and power factor, ripple and regulation accuracy, and protection trip values, with per-unit records kept for traceability.
Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.
Correct installation and commissioning directly affect service life. After positioning, the cabinet is levelled and secured, incoming and outgoing cables are checked for phase sequence and polarity, and power cable cross-sections are chosen for both ampacity and permissible voltage drop. Before energising, insulation resistance is measured and short circuits ruled out; the first start uses soft start or low-voltage trial operation to verify bus establishment, fan direction and communication, then loading proceeds gradually with temperature rise recorded.