Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply

Product Center / Rectifier Power Supply

Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply

Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Rectifier Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.

Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply manufacturer-direct supply with custom engineering, selection calculation, drawing confirmation and on-site commissioning.
Contact Us 0531-68684888

Product Introduction

This series converts three-phase AC into regulated DC and covers three technology routes: thyristor phase control, diode rectification and high-frequency IGBT PWM. The key specifications are output voltage and current accuracy, ripple factor, power factor and harmonic content. Typical applications include electrolysis, electroplating, charging, telecom, data centres and industrial DC busbars.

The unit comprises an input breaker and protection stage, a rectifier transformer or high-frequency isolation transformer, the rectifier or chopper power stage, output filtering, measurement and digital control, and cooling. Phase-controlled models use thyristor phase shift for regulation and are robust against surge; high-frequency models use IGBT chopping or PWM rectification for lower harmonics, higher power factor and much reduced size and weight.

In Rectifier Power Supply selection and deployment, EMC, grounding practice and cable routing often matter more than single-unit specifications, so filtering and shielding follow industrial site standards.

Every unit is full-load burned in and waveform tested before dispatch, with a test report and wiring diagram supplied for acceptance and maintenance.

Working Principle

The basic phase-controlled relationship is Ud = Ud0·cosα, where Ud0 is the ideal no-load DC voltage at zero firing angle and α is the firing delay angle. Output is regulated continuously by changing α, at the cost of reduced power factor and increased harmonics at deep retard. In practice an on-load tap changer is combined with phase control so that α stays within a shallow 10°–30° window, balancing regulation range and power quality.

The pulse number determines harmonic behaviour. A six-pulse rectifier produces characteristic grid harmonics of the 5th, 7th, 11th and 13th order with a current THD typically of 25%–30%. A twelve-pulse arrangement uses two transformers with Y/Δ and Y/Y connections shifted by 30°, raising the lowest characteristic orders to the 11th and 13th and reducing THD to 8%–10%. Twenty-four-pulse systems reach 3%–4%. Where limits are strict, passive or active filters are added.

PWM rectification (active front end) uses IGBT switches with a boost inductor and a current loop to shape the grid current into a sinusoid in phase with the voltage. Power factor exceeds 0.99, input current THD is below 5% and energy can flow in both directions. Vienna and T-type three-level topologies reduce device voltage stress and switching loss in medium and high power, and are widely used in data-centre and charging-pile DC busbars.

Output ripple is suppressed by LC or π filters. The ripple factor γ = ΔU/Ud is typically ≤1% for industrial models, ≤0.5% for plating and electrolysis where coating quality is sensitive, and down to 0.1% for precision test applications. Ripple frequency depends on pulse number and switching frequency; the filter inductor is designed at the critical inductance while the capacitor balances ripple current and service life.

Control uses a dual-loop structure with an outer voltage loop and an inner current loop, switching automatically between constant-voltage and constant-current modes. Parallel units use master-slave or droop current sharing with errors below 3%; combined with N+1 redundancy and hot-swap construction, a faulty module can be replaced without shutdown. For protection, IGBTs use desaturation detection for microsecond short-circuit protection, while thyristor stages rely on fast fuses and electronic protection boards.

Device derating and lifetime are key constraints of this series. Electrolytic capacitor life roughly halves for every 10 °C rise, so selection checks both ripple current and case temperature, and capacitors are placed away from heat sources and airflow dead zones. IGBT and SiC modules are derated to a junction temperature below 125 °C (150 °C for SiC), with short-circuit withstand time and thermal cycling capability verified to keep margin under frequent start-stop and load swings.

Paralleling and redundancy are common means of improving availability. Modules share current by master-slave or droop control with errors within 3%. In an N+1 arrangement a failed module is automatically replaced by the remaining units and can be withdrawn for replacement online. Paralleled systems need a common voltage reference and slew rate to avoid circulating current, and DC-side sharing reactors or separate output cables further suppress imbalance.

Key Features

  • High efficiency: ≥96% at full load for high-frequency models and ≥94% for phase-controlled models, maintained over a wide range with on-load tap changing.
  • Low harmonics and high power factor: twelve or twenty-four pulse, or AFE, with grid THD ≤5% and power factor ≥0.99.
  • High accuracy: voltage and current regulation within 0.5%, ripple factor ≤1% (optionally ≤0.1%).
  • Comprehensive protection: overvoltage, overcurrent, short circuit, phase loss, overtemperature, fan failure and insulation monitoring, with traceable fault codes.
  • The efficiency curve stays flat from 50% to 100% load, with an automatic energy-saving mode at light load.
  • Cabinet temperature, humidity and dust status are monitored, giving early warning instead of an abrupt trip.

Main features:

Technical Parameters

ModelRectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply
CategoryRectifier Power Supply series
InputThree-phase 380/400/480/690 V, 50/60 Hz
Output DC voltage0–1000 V (up to 35 kV on request)
Output DC current0–50 kA (model dependent)
Voltage/current accuracy≤0.5%
Ripple factor≤1% (optionally ≤0.1%)
Related ratingsCustomized to application (Rectifier Power Supply series)
CoolingWater-cooled / air-cooled by power class
ProtectionOvervoltage, overcurrent, short circuit, overtemperature, phase loss, interlock
CommunicationRS485 Modbus / Ethernet / analogue (optional)

Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.

Applications

  • Charging and storage: DC charging modules, auxiliary supplies for storage PCS and battery cluster feeding.
  • Industrial DC busbars: DC drives in metallurgy, chemicals, glass and paper production lines.
  • Rail transit and marine: traction substations, shore power and marine DC distribution.
  • Test and burn-in: laboratory DC sources, device aging and factory inspection supplies.
  • Electrolysis and electroplating: high-current low-voltage DC output with multi-pulse rectification to reduce harmonics.
  • Telecom and data centres: 48 V, 240 V and 336 V DC power systems and HVDC column cabinets.

Typical applications of Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply include:

Selection Guide

Select the pulse number or AFE scheme according to grid harmonic limits: six-pulse for low power and lenient limits, twelve or twenty-four pulse for medium and large electrolysis and metallurgy, and AFE where power factor and regeneration matter.

Choose the filter type from the process ripple requirement: ≤1% for general industry, ≤0.5% for plating, ≤0.1% for precision testing. Each step up in ripple performance noticeably increases inductor and capacitor size and cost.

Confirm cooling and environment: air-cooled units need clean inlet air at controlled temperature; water-cooled units need circulating water at the specified pressure and flow; corrosive sites require protective coating or isolated air ducts.

Fault diagnosis and predictive maintenance rely on comprehensive monitoring points. The unit continuously acquires bus voltage, output current, device temperature, coolant flow and fan speed, triggering alarms or derating according to severity and storing fault codes, timestamps and key waveforms in non-volatile memory. Host software exports historical curves and estimates remaining life from accumulated operating hours and thermal cycles, turning corrective maintenance into planned maintenance.

If the local grid fluctuates or large equipment starts frequently, verify the input undervoltage and overvoltage protection range and the auto-recovery strategy.

Operation & Maintenance

Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.

Wide-bandgap devices significantly shift the power-density boundary. SiC MOSFETs have about ten times the breakdown field of silicon, so the drift layer is thinner and on-resistance lower at the same rating. With switching frequencies above 40 kHz, magnetic components shrink by more than half and efficiency improves by one to two percentage points. The trade-off is higher dv/dt and di/dt, which place stricter demands on gate drivers, busbars and filtering.

High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.

Output filtering and ripple control involve a trade-off between size, cost and performance. A larger inductor reduces ripple but slows dynamic response and increases copper loss; a higher switching frequency shrinks the inductor but raises switching loss and EMI. In practice, interleaved multiphase operation raises the effective ripple frequency, LC and pi filters suppress high-frequency components, and low-ESR capacitors at the output improve transient response.

FAQ

What does a twelve-pulse rectifier improve over a six-pulse design?
A twelve-pulse arrangement uses two transformers shifted by 30°, raising the lowest characteristic harmonics from the 5th and 7th to the 11th and 13th. Grid current THD drops from about 25%–30% to 8%–10%, and the DC ripple frequency doubles so filter components can be smaller. The cost is more transformers and rectifier devices.
Why does power factor fall at deep phase retard?
A phase-controlled rectifier draws a square-wave current lagging the voltage, and the fundamental displacement factor is approximately cosα. A larger firing angle means more fundamental lag, lower power factor and higher reactive demand. On-load tap changing, reactive compensation or PWM rectification are the usual remedies.
How is current sharing guaranteed when several units are paralleled?
Master-slave and droop sharing are both common. In master-slave the host issues the current reference and the followers track it, giving high accuracy. Droop sharing adjusts each module voltage reference according to its own current without communication, giving high reliability with slightly lower accuracy. Sharing error is normally kept within 3%.
What are the installation requirements for Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply?
Install in a well-ventilated area free of conductive dust and corrosive gas, with ambient temperature from -10 to 40 °C (up to 50 °C for water-cooled models) and at least 800 mm maintenance clearance front and rear. Water-cooled models require circulating water at the specified pressure and flow with inlet temperature not above 32 °C. Ground resistance should be below 4 ohm and power and signal cables should be routed in separate trays.
What is the lead time and customisation scope for Rectifier Power Supply / Electrodialysis Rectifier Power Supply / Naturally Cooled Rectifier Power Supply?
Standard ratings are delivered within the agreed period after contract effectiveness. Output voltage, current, communication protocol, cabinet dimensions and protection class can all be customised; custom models require load characteristics, operating environment and interface requirements for the electrical and mechanical design.
← Aviation Power Supply / Compact Aviation Power Supply / Mid-Frequency Aviation Power Supply Hard Chrome Electroplating Power Supply / Liquid-Cooled Hard Chrome Electroplating Power Supply / Low-Ripple Hard Chrome Electroplating Power Supply →