Customized Power Supply / Wall-Mounted Customized Power Supply / Three-Phase Customized Power Supply from Jinan Nenghua Electromechanical Equipment Co., Ltd., designed for Customized Power Supply and its series applications, with engineering customisation to load profile, process requirements and site conditions.

Customized Power Supply / Wall-Mounted Customized Power Supply / Three-Phase Customized Power Supply manufacturer-direct supply with custom engineering, selection calculation, drawing confirmation and on-site commissioning.
Contact Us 0531-68684888

Product Introduction

This series is a voltage-class family of DC power supplies covering 24 V, 48 V, 110 V and 220 V industrial and power-operation levels, 750 V, 1000 V and 1500 V storage and charging platform levels, and high-voltage DC duties from 3000 V up to 35 kV. Each class carries its own device ratings, insulation distances and topology, with efficiency, ripple, protection and communication tailored to the application.

The unit comprises an input rectifier or PFC stage, an isolated or non-isolated DC/DC stage, output filtering, sensing and digital control, protection and communication, and cooling. Low-voltage high-current models use synchronous rectification and multiphase paralleling to cut conduction loss; high-voltage models use three-level or multilevel structures to reduce device stress; stringent insulation duties use dry-type or oil-immersed construction with partial-discharge control.

For Customized Power Supply site requirements the enclosure separates power, control and cabling compartments, so routine maintenance does not require a full shutdown.

Modular construction allows power units, control boards and fans to be replaced independently, with common spares reducing lifetime maintenance cost.

Working Principle

Voltage class sets device and insulation selection. A 220 V DC bus can use 650 V devices, a 750 V bus typically uses 1200 V devices, and a 1500 V bus uses 1700 V or 3300 V devices with three-level topologies that halve the per-device stress. Each step up in voltage raises creepage distance, clearance and tracking-index requirements, and changes enclosure size and thermal design.

Typical topologies use a two-stage structure of PFC followed by an LLC resonant or phase-shifted full-bridge converter. The front stage shapes the input current into a sinusoid and provides a regulated bus, while the rear stage provides isolation and regulation through a high-frequency transformer. LLC operating near resonance achieves zero-voltage turn-on on the primary and zero-current turn-off on the secondary rectifiers, reaching efficiency above 96%. For medium and high power with wide voltage range, the dual active bridge (DAB) provides bidirectional energy flow and wide regulation through phase-shift control.

The 1500 V DC platform is now mainstream for storage and PV. Compared with 1000 V systems the current is one third lower at the same power, cutting line loss and copper usage. However DC arcs are harder to extinguish, so dedicated DC breakers, fuses and arc-fault detection are mandatory, together with reverse-polarity protection and a visible isolation point for maintenance. SiC devices raise switching frequency to 40–100 kHz, pushing converter efficiency above 98% and shrinking magnetic components.

Ripple, accuracy and dynamic response are the three basic performance metrics. Ripple is set by switching frequency and output filtering, typically ≤1% for industrial models and ≤0.1% for test and research models. Voltage accuracy is typically ±0.5%, reaching ±0.05% in high-precision models. Dynamic response is measured as the recovery time to ±1% after a load step, with fast models below 1 ms.

Protection and monitoring must address overvoltage, overcurrent, short circuit, reverse polarity, insulation degradation and DC arcing. An insulation monitoring device (IMD) injects a low-frequency signal or measures the asymmetry of positive and negative rail voltages to earth. DC breakers must extinguish arcs and break in both directions. Charging and storage systems also need pre-charge circuits to limit inrush and protect bus capacitors.

Device derating and lifetime are key constraints of this series. Electrolytic capacitor life roughly halves for every 10 °C rise, so selection checks both ripple current and case temperature, and capacitors are placed away from heat sources and airflow dead zones. IGBT and SiC modules are derated to a junction temperature below 125 °C (150 °C for SiC), with short-circuit withstand time and thermal cycling capability verified to keep margin under frequent start-stop and load swings.

EMC performance depends on the combination of filtering, shielding and grounding. Input common-mode and differential-mode filter networks suppress conducted interference, snubber capacitors and RC networks reduce device dv/dt, and the enclosure uses continuous welding or conductive gaskets to maintain shielding integrity. Grounding follows single-point practice with separate power and signal grounds, shielded layers grounded at one end to avoid ground loops, and twisted shielded signal cables routed separately from power cables.

Key Features

  • High-efficiency topologies: LLC resonant, phase-shifted full bridge and DAB, with full-load efficiency ≥96% and up to 98% with SiC.
  • High accuracy: voltage regulation ±0.5% (±0.05% optional), ripple ≤1% (≤0.1% optional).
  • Bidirectional and regenerative: DAB and four-quadrant topologies support bidirectional energy flow with regeneration efficiency ≥95%.
  • DC safety design: insulation monitoring, arc-fault detection, reverse-polarity protection, pre-charge limiting and a visible isolation point.
  • Industrial or automotive-grade components are used, with capacitors, fans and contactors selected for long life.
  • Multiple process recipes can be stored and recalled, avoiding repeated adjustment during product changeover.

Main features:

Technical Parameters

ModelCustomized Power Supply / Wall-Mounted Customized Power Supply / Three-Phase Customized Power Supply
CategoryCustomized Power Supply series
Output voltage range24 V–35 kV (voltage-class family)
Output power0.5 kW–2 MW (parallel expandable)
Voltage accuracy±0.5% (±0.05% optional)
Ripple factor≤1% (≤0.1% optional)
Full-load efficiency≥96% (≥98% with SiC)
Related ratingsCustomized to application (Customized Power Supply series)
CoolingWater-cooled / air-cooled by power class
ProtectionOvervoltage, overcurrent, short circuit, overtemperature, phase loss, interlock
CommunicationRS485 Modbus / Ethernet / analogue (optional)

Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.

Applications

  • Industry and test: plating, electrolysis, electrostatic precipitation, device burn-in and laboratory DC sources.
  • Storage and PV: battery cluster supply, auxiliary supplies for storage PCS, MPPT feeding and combiner-box supplies.
  • Charging and battery swap: DC charging modules, charging stacks, liquid-cooled ultra-fast charging and V2G bidirectional conversion.
  • Data centres and telecom: 240/336/400/480 V HVDC feeding, DC column cabinets and server power supplies.
  • Power operation supplies: 110/220 V DC panels, substation operation supplies and relay protection supplies.
  • Rail transit and marine: 750/1500 V traction supply, vehicle auxiliary supplies and shore-side DC distribution.

Typical applications of Customized Power Supply / Wall-Mounted Customized Power Supply / Three-Phase Customized Power Supply include:

Selection Guide

Determine the construction by insulation and safety requirements: high-voltage duties need creepage and clearance verification, sometimes oil-immersed or gas-insulated construction with partial-discharge testing.

Determine filtering and control by accuracy requirements: test applications need low ripple and high-resolution sensing, while industrial applications can relax these to reduce cost.

Confirm communication protocols and paralleling requirements: Modbus, CAN, Ethernet and dry-contact alarms, together with current-sharing method and master-slave settings.

High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.

When several units are installed together, calculate the total heat dissipation and ventilation of the room, adding exhaust or a chiller if required.

Operation & Maintenance

Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.

The digital control platform uses a DSP for the main control loop and an FPGA for high-speed timing and multi-channel sampling, exchanging data over a parallel bus. Current and voltage are sensed with isolated amplifiers or Hall sensors, whose sampling rate and resolution set the upper limit of loop bandwidth. Voltage and current loop crossover frequencies are set to one third to one fifth of the load time constant, balancing response and stability. Parameters can be read, written and backed up from the host computer for batch replication.

High altitude and extreme environments impose additional requirements. Above 1000 m the dielectric strength and cooling capability of air both fall, so derating of 5%–10% per additional 1000 m and larger clearances are applied. Low-temperature sites need low-temperature electrolytic capacitors and anti-condensation heaters, while humid sites need conformal coating and condensation control. Outdoor models also require sun, rain, dust and theft protection with cabinet temperature held by air conditioning or heat exchangers.

Input power quality is an often overlooked hidden cost. Phase-controlled rectifiers lose power factor and increase harmonics at large firing angles, requiring reactive compensation and filtering. High-frequency rectifiers correct power factor but also see efficiency and power factor fall at light load. On-load tap changing, staged switching or multi-pulse schemes keep power factor above 0.9, reducing utility penalties and disturbance to other equipment on the same network.

FAQ

What are the practical benefits of 1500 V DC over 1000 V?
At the same power the bus current is about one third lower, line loss falls with the square of current, and cable and busbar usage is reduced, lowering cost and footprint. The trade-off is higher device voltage rating, DC arc extinction and insulation monitoring requirements, with dedicated DC breakers and arc-fault detection.
How should LLC and phase-shifted full bridge be chosen?
LLC is most efficient near resonance with low EMI and suits applications with limited output voltage variation. Phase-shifted full bridge maintains good performance over a wide range with simple control. If bidirectional energy flow is required, a DAB should be selected.
Why can't AC earth-leakage protection replace insulation monitoring in DC systems?
AC leakage protection cannot identify simultaneous insulation degradation of both DC rails to earth, and DC arcs have no natural zero crossing, so they do not self-extinguish. Dedicated insulation monitoring devices continuously measure insulation resistance to earth, combined with DC breakers and arc-fault detection.
What are the installation requirements for Customized Power Supply / Wall-Mounted Customized Power Supply / Three-Phase Customized Power Supply?
Install in a well-ventilated area free of conductive dust and corrosive gas, with ambient temperature from -10 to 40 °C (up to 50 °C for water-cooled models) and at least 800 mm maintenance clearance front and rear. Water-cooled models require circulating water at the specified pressure and flow with inlet temperature not above 32 °C. Ground resistance should be below 4 ohm and power and signal cables should be routed in separate trays.
What is the lead time and customisation scope for Customized Power Supply / Wall-Mounted Customized Power Supply / Three-Phase Customized Power Supply?
Standard ratings are delivered within the agreed period after contract effectiveness. Output voltage, current, communication protocol, cabinet dimensions and protection class can all be customised; custom models require load characteristics, operating environment and interface requirements for the electrical and mechanical design.