Product Introduction

This series converts three-phase AC into regulated DC and covers three technology routes: thyristor phase control, diode rectification and high-frequency IGBT PWM. The key specifications are output voltage and current accuracy, ripple factor, power factor and harmonic content. Typical applications include electrolysis, electroplating, charging, telecom, data centres and industrial DC busbars.

The unit comprises an input breaker and protection stage, a rectifier transformer or high-frequency isolation transformer, the rectifier or chopper power stage, output filtering, measurement and digital control, and cooling. Phase-controlled models use thyristor phase shift for regulation and are robust against surge; high-frequency models use IGBT chopping or PWM rectification for lower harmonics, higher power factor and much reduced size and weight.

In practical Heating Power Supply installations the unit must hold its output stable against load impedance variation, ambient temperature swings and continuous duty, so device derating, thermal margin and protection thresholds all carry reserve.

Modular construction allows power units, control boards and fans to be replaced independently, with common spares reducing lifetime maintenance cost.

Working Principle

The basic phase-controlled relationship is Ud = Ud0·cosα, where Ud0 is the ideal no-load DC voltage at zero firing angle and α is the firing delay angle. Output is regulated continuously by changing α, at the cost of reduced power factor and increased harmonics at deep retard. In practice an on-load tap changer is combined with phase control so that α stays within a shallow 10°–30° window, balancing regulation range and power quality.

The pulse number determines harmonic behaviour. A six-pulse rectifier produces characteristic grid harmonics of the 5th, 7th, 11th and 13th order with a current THD typically of 25%–30%. A twelve-pulse arrangement uses two transformers with Y/Δ and Y/Y connections shifted by 30°, raising the lowest characteristic orders to the 11th and 13th and reducing THD to 8%–10%. Twenty-four-pulse systems reach 3%–4%. Where limits are strict, passive or active filters are added.

PWM rectification (active front end) uses IGBT switches with a boost inductor and a current loop to shape the grid current into a sinusoid in phase with the voltage. Power factor exceeds 0.99, input current THD is below 5% and energy can flow in both directions. Vienna and T-type three-level topologies reduce device voltage stress and switching loss in medium and high power, and are widely used in data-centre and charging-pile DC busbars.

Output ripple is suppressed by LC or π filters. The ripple factor γ = ΔU/Ud is typically ≤1% for industrial models, ≤0.5% for plating and electrolysis where coating quality is sensitive, and down to 0.1% for precision test applications. Ripple frequency depends on pulse number and switching frequency; the filter inductor is designed at the critical inductance while the capacitor balances ripple current and service life.

Control uses a dual-loop structure with an outer voltage loop and an inner current loop, switching automatically between constant-voltage and constant-current modes. Parallel units use master-slave or droop current sharing with errors below 3%; combined with N+1 redundancy and hot-swap construction, a faulty module can be replaced without shutdown. For protection, IGBTs use desaturation detection for microsecond short-circuit protection, while thyristor stages rely on fast fuses and electronic protection boards.

Thermal design determines whether the unit can run at full load continuously. Air-cooled models use zoned airflow with front-to-rear heatsink layout, fin spacing matched to air velocity to reduce pressure drop. Water-cooled models use a cold plate with independent channels, thermal grease or phase-change material to lower contact resistance, and outlet temperature and flow sensors. Overall thermal resistance is calculated for the worst case of maximum ambient, full load and half-blocked filters.

Wide-bandgap devices significantly shift the power-density boundary. SiC MOSFETs have about ten times the breakdown field of silicon, so the drift layer is thinner and on-resistance lower at the same rating. With switching frequencies above 40 kHz, magnetic components shrink by more than half and efficiency improves by one to two percentage points. The trade-off is higher dv/dt and di/dt, which place stricter demands on gate drivers, busbars and filtering.

Key Features

  • Low harmonics and high power factor: twelve or twenty-four pulse, or AFE, with grid THD ≤5% and power factor ≥0.99.
  • High accuracy: voltage and current regulation within 0.5%, ripple factor ≤1% (optionally ≤0.1%).
  • N+1 redundant parallel operation: master-slave current sharing within 3%, hot-swap and online maintenance.
  • Comprehensive protection: overvoltage, overcurrent, short circuit, phase loss, overtemperature, fan failure and insulation monitoring, with traceable fault codes.
  • The efficiency curve stays flat from 50% to 100% load, with an automatic energy-saving mode at light load.
  • Multiple process recipes can be stored and recalled, avoiding repeated adjustment during product changeover.

Main features:

Technical Parameters

ModelHeating Power Supply / Heating-wire Heating Power Supply / Through-heating Power Supply
CategoryHeating Power Supply series
InputThree-phase 380/400/480/690 V, 50/60 Hz
Output DC voltage0–1000 V (up to 35 kV on request)
Output DC current0–50 kA (model dependent)
Voltage/current accuracy≤0.5%
Ripple factor≤1% (optionally ≤0.1%)
Related ratingsCustomized to application (Heating Power Supply series)
CoolingWater-cooled / air-cooled by power class
ProtectionOvervoltage, overcurrent, short circuit, overtemperature, phase loss, interlock
CommunicationRS485 Modbus / Ethernet / analogue (optional)

Parameters above are for reference; final specs subject to the technical agreement / order contract. Non-standard customization is available.

Applications

  • Telecom and data centres: 48 V, 240 V and 336 V DC power systems and HVDC column cabinets.
  • Charging and storage: DC charging modules, auxiliary supplies for storage PCS and battery cluster feeding.
  • Industrial DC busbars: DC drives in metallurgy, chemicals, glass and paper production lines.
  • Rail transit and marine: traction substations, shore power and marine DC distribution.
  • Test and burn-in: laboratory DC sources, device aging and factory inspection supplies.
  • Electrolysis and electroplating: high-current low-voltage DC output with multi-pulse rectification to reduce harmonics.

Typical applications of Heating Power Supply / Heating-wire Heating Power Supply / Through-heating Power Supply include:

Selection Guide

Select the pulse number or AFE scheme according to grid harmonic limits: six-pulse for low power and lenient limits, twelve or twenty-four pulse for medium and large electrolysis and metallurgy, and AFE where power factor and regeneration matter.

Choose the filter type from the process ripple requirement: ≤1% for general industry, ≤0.5% for plating, ≤0.1% for precision testing. Each step up in ripple performance noticeably increases inductor and capacitor size and cost.

Confirm cooling and environment: air-cooled units need clean inlet air at controlled temperature; water-cooled units need circulating water at the specified pressure and flow; corrosive sites require protective coating or isolated air ducts.

Design and testing follow the GB/T 3859 semiconductor converter standard, GB 17625 harmonic limits, GB/T 2423 environmental test series and IEC 61000 immunity requirements; export models additionally meet the relevant CE or UL clauses. Factory tests typically cover insulation resistance and withstand voltage, full-load temperature rise, efficiency and power factor, ripple and regulation accuracy, and protection trip values, with per-unit records kept for traceability.

Where budget allows, choose one power class higher: the difference in temperature rise and life under continuous full load far outweighs the purchase price.

Operation & Maintenance

Cooling and maintenance: water-cooled models require stable water quality and flow, with periodic cleaning of the plate heat exchanger and strainers, and draining before freezing weather. Air-cooled models need regular cleaning of inlet filters and heatsinks to prevent derating from blocked airflow. After long shutdown, perform an insulation check and low-voltage trial run before returning to service.

Thermal design determines whether the unit can run at full load continuously. Air-cooled models use zoned airflow with front-to-rear heatsink layout, fin spacing matched to air velocity to reduce pressure drop. Water-cooled models use a cold plate with independent channels, thermal grease or phase-change material to lower contact resistance, and outlet temperature and flow sensors. Overall thermal resistance is calculated for the worst case of maximum ambient, full load and half-blocked filters.

EMC performance depends on the combination of filtering, shielding and grounding. Input common-mode and differential-mode filter networks suppress conducted interference, snubber capacitors and RC networks reduce device dv/dt, and the enclosure uses continuous welding or conductive gaskets to maintain shielding integrity. Grounding follows single-point practice with separate power and signal grounds, shielded layers grounded at one end to avoid ground loops, and twisted shielded signal cables routed separately from power cables.

Output filtering and ripple control involve a trade-off between size, cost and performance. A larger inductor reduces ripple but slows dynamic response and increases copper loss; a higher switching frequency shrinks the inductor but raises switching loss and EMI. In practice, interleaved multiphase operation raises the effective ripple frequency, LC and pi filters suppress high-frequency components, and low-ESR capacitors at the output improve transient response.

FAQ

What does a twelve-pulse rectifier improve over a six-pulse design?
A twelve-pulse arrangement uses two transformers shifted by 30°, raising the lowest characteristic harmonics from the 5th and 7th to the 11th and 13th. Grid current THD drops from about 25%–30% to 8%–10%, and the DC ripple frequency doubles so filter components can be smaller. The cost is more transformers and rectifier devices.
Why does power factor fall at deep phase retard?
A phase-controlled rectifier draws a square-wave current lagging the voltage, and the fundamental displacement factor is approximately cosα. A larger firing angle means more fundamental lag, lower power factor and higher reactive demand. On-load tap changing, reactive compensation or PWM rectification are the usual remedies.
How is current sharing guaranteed when several units are paralleled?
Master-slave and droop sharing are both common. In master-slave the host issues the current reference and the followers track it, giving high accuracy. Droop sharing adjusts each module voltage reference according to its own current without communication, giving high reliability with slightly lower accuracy. Sharing error is normally kept within 3%.
What are the installation requirements for Heating Power Supply / Heating-wire Heating Power Supply / Through-heating Power Supply?
Install in a well-ventilated area free of conductive dust and corrosive gas, with ambient temperature from -10 to 40 °C (up to 50 °C for water-cooled models) and at least 800 mm maintenance clearance front and rear. Water-cooled models require circulating water at the specified pressure and flow with inlet temperature not above 32 °C. Ground resistance should be below 4 ohm and power and signal cables should be routed in separate trays.
What is the lead time and customisation scope for Heating Power Supply / Heating-wire Heating Power Supply / Through-heating Power Supply?
Standard ratings are delivered within the agreed period after contract effectiveness. Output voltage, current, communication protocol, cabinet dimensions and protection class can all be customised; custom models require load characteristics, operating environment and interface requirements for the electrical and mechanical design.