The most common inverter selection mistake is buying to the load's rated power and then finding it cannot start. The reason is that many loads draw a starting surge far above their rating. A few key points are enough to get capacity and type right.
| Load type | Starting behaviour | Sizing rule |
|---|---|---|
| Incandescent lamps, heaters | No surge | Use rated power |
| Motors, pumps, compressors | Starting current several times rated | Use surge power with margin |
| Switch-mode equipment | Large inrush at power-on | Account for the transient |
| Several devices combined | Probability of simultaneous start | Calculate the worst case |
The inverter must match the DC side: common levels are 12 V, 24 V, 48 V and higher system voltages. Higher voltage means lower current for the same power and less line loss, so match the battery bank or DC bus voltage.
Size for the worst starting condition, not for the load's nameplate power. See inverters and locomotive inverters; the full range is in the inverter category.